        [Concern] California of the United States issued the AB 2208 Act to phase out mercury-containing fluorescent lamps

        Author:中認聯(lián)科 time:2023-01-11 Ctr:1731

        On September 20, 2022, California signed the AB 2208 Act, which will phase out and prohibit the sale of mercury-containing fluorescent lamps in California. From January 1, 2024, spiral or bayonet compact fluorescent lamps shall not be sold in California as newly manufactured products; From January 1, 2025, pin type compact fluorescent lamps and linear fluorescent lamps shall not be sold in California as newly manufactured products.

        About compact fluorescent lamps

        Compact fluorescent lamp refers to a compact low-voltage mercury-containing discharge light source, wherein the fluorescent coating converts part of the ultraviolet energy generated by mercury discharge into visible light, and includes the following features:

        1. Single-ended power supply, lamp holder including but not limited to screw type, bayonet type, two pins and four pins;

        2. Integrated ballast or non-integrated ballast;

        3. The color temperature is between 1700K and 24000K, and the DUV is between+0.024 and -0.024;

        4. Fluorescent lamps of all diameters and lengths;

        5. Fluorescent lamps of all sizes and shapes for directional and non-directional installation, including but not limited to PL, spiral, double tube, triple double tube, 2D, U-shaped and round.

        About Linear Fluorescent Lamps

        Linear fluorescent lamp refers to a low voltage mercury-containing discharge light source, wherein the fluorescent coating converts part of the ultraviolet energy generated by mercury discharge into visible light, and includes the following features:

        1. Two-terminal power supply, lamp holder includes but is not limited to single-pin, two-pin, concave double-contact;

        2. The color temperature is between 1700K and 24000K, and the DUV is between+0.024 and -0.024;

        3. All lamp diameters, including but not limited to T5, T8, T10 and T12;

        4. The length of lamp tube is between 0.5 and 8.0 feet;

        5. All lamp tube shapes, including but not limited to linear, U-shaped and circular.

        The bill exempted the following special purpose fluorescent lamps

        1. Lamp for image capture and projection; Including copying, printing, direct or pre-processing, lithography, film and video projection and holography;

        2. High UV content and one of the following products:

        ? High UV content and UV power greater than 2 mW/klm;

        ? Lamps used for sterilization, such as DNA destruction, with a peak wavelength of about 253.7 nm;

        ? For lamps used for disinfection or fly catching, between 250 and 800 nm, the radiation power at the wavelength of 250 to 315 nm accounts for at least 5% of the total radiation, or the radiation power at the wavelength of 315 to 400 nm accounts for at least 20% of the total radiation;

        ? Lamps used to generate ozone, whose main purpose is to emit radiation of about 185.1 nm;

        ? Lamps used for symbiosis of corals, yellow algae, and yellow algae, whose radiation power of 400 to 480 nm accounts for at least 40% of the total radiation power of 250 to 800 nm;

        ? Sunlight, which is designed to contain one or more ultraviolet lamps, is used to irradiate any part of the human body through ultraviolet radiation with a wavelength between 200 and 400 nm in the air to induce skin tanning.

        3. Lamp for medical or veterinary diagnosis or treatment, or for medical equipment;

        4. Lamps for manufacturing or quality control of pharmaceutical products;

        5. Lamps for spectroscopic and photometric applications; For example, ultraviolet-visible spectroscopy, molecular spectroscopy, atomic absorption spectroscopy, non-dispersive infrared (NDIR), Fourier transform infrared (FTIR), medical analysis, ellipsometry, layer thickness measurement, process monitoring or environmental monitoring;

        6. A lamp used by academic and research institutions to conduct research projects and experiments.

        Warm tips

        With the continuous updating of California regulations, enterprises are facing more and more control requirements. ZRLK suggests that relevant enterprises improve their product risk awareness, pay attention to the update of California regulations, adjust production strategies, ensure that the exported lamps and lanterns meet the latest regulatory requirements, and avoid trade risks. Our company has a wide range of testing areas and a professional and efficient service team, which can help you easily understand whether the product is safe and compliant. If you need, please feel free to contact us, and our engineers will serve you at the first time!

        Related Articles
        • Win the Market with Valid Certificates: Must-Know Guide to CCC Certification for Neck Fan Batteries

        • Empower Overseas Expansion with Compliance: Core Value of UN38.3 Certification for Robot Vacuum Cleaner Batteries

        • Efficient UN38.3 Certification: Help Drones Capture Overseas Market Share

        • CCC Certification for Power Banks: A Must for Compliant Operation to Unlock New Market Opportunities

        Follow Us
        主站蜘蛛池模板: 欧美性猛交一区二区三区| 婷婷久久香蕉五月综合加勒比 | 一区二区三区国产偷拍| 久久综合伊人77777| 久久亚洲精品成人无码网站夜色 | 天天综合色中文字幕在线视频| 亚洲日韩AV秘 无码一区二区 | 欧美亚洲综合久久偷偷人人| 色AV专区无码影音先锋| 亚洲区日韩| 亚洲成人电影中文字幕| 一级爱一级做a性视频| 欧美人与禽2o2o性论交| 51国产在线| 99re在线观看视频| 色一情一区二区三区四区| 免费AV片在线观看网址| 国产va免费精品观看| 日韩免费毛片变态另| 亚洲成a人片在线观看日本| 少妇人妻偷人偷人精品| 久久久噜噜噜久久中文字幕色伊伊 | 免费无码一区二区三区蜜桃| 九九在线精品国产| 女生洗鸡鸡喷尿的视频无马赛克?舒坦直叫的骚货视频?亚洲着九九九视频影 | 亚洲中文无码一区| 久操超碰| 亚洲精品无码高潮喷水A| 伊人99在线| 金寨县| 丁香五月av| 午夜成人性爽爽免费视频| 91人妻人人澡人人爽人人精品| 亚洲人妻乱| 免费男人j桶进女人p无遮挡动态图 | av熟女在线更新| 疏附县| 日本在线一区二区观看| 亚洲乱理伦片在线观看中字| 中文原创av| 国产国语一级毛片|